Building Specification

Slab to Slab Height
Typical floor benefit from a 4 m (approx. 13'-0'') height

Finished Floor to Ceiling Height
Typical floor 3.325 m (approx. 11'-0'') from floor to exposed ceiling

Structural Grid
Typically 9 m x 9 m (approx. 30' x 30') structural grid
1.5m (approx. 5')  module on the exterior wall

Floor Loadings
Reinforced concrete construction flat slab with drop panels following at 9 m x 9 m grid

Floor loading design:
-Ground floor 100 lbs + 25 lbs per square foot
-Typical floor 100 lbs + 10 lbs per square foot

Raised Floors
450 mm (18") overall depth including floor finishes for HVAC, electrical and data distribution

HVAC
Distribution by raised floors

Lighting
500 Lux (average) at desk level in open landscape environment

Life Safety and Security
24 hour security-electronically controlled access

Elevators
Passenger: 12 cabins in 2 banks for the tower
Freight: 1 service-freight elevator reaching all the floors
3 cabins in 1 bank for the podium towers

 


Click on image to enlarge
Stacking Plan

TOTAL GROSS LEASEABLE AREA
769,770 square feet (71,552 m²)

32nd Floor
11,910 square feet (1,106 m²)

29th-31st Floors
13,000 square feet (1,208 m²)

18th-28th Floors
21,965 square feet (2,041 m²)

5th-17th Floors
21,405 square feet (1,989 m²)

2nd-4th Floors (Podium)
50,585 square feet (4,699 m²)

Ground Floor
47,225 square feet (4,387 m²)


Click on image to enlarge
Typical Floor Plan

Typical Floor - Upper Levels
Click here to download the pdf version.

Typical Floor - Lower Levels
Click here to download the pdf version.

Site Plan
Click here to download the pdf version.

If you do not have Adobe Acrobat Reader, you can download it by clicking the link below:

Adobe Logo


Click on image to enlarge
Copyright © Magil Laurentian, 2009 Magil Laurentian Logo